| A.M. Metal Finishing, Inc. | Phosphate Coating: Light |
| Quality & Service Through Experience | |
. |
|
| Back | Home | |
| Phosphate
Coating: Light [TT-C-490D] Specification covers cleaning methods and pre-treatment processes Type I: Intended as a general all-purpose pretreatment prior to painting. Type II & IV: Intended primarily for use where metal parts are to be formed after painting. Type III: Intended for use where size and shape preclude using types I, II or IV and where items containing mixed metal components are assembled prior to treatment. Note: Cleaning material shall not contain any chemical which is classified in the Clean Air Act Amendments of 1990 as a Class I or Class II ozone depleting substance. Light coating for use as a paint base. Cleaning Methods: Method I: Mechanical or abrasive cleaning (for ferrous surfaces only). Method II: Solvent cleaning. Method III: Hot alkaline (for ferrous surfaces only). Method IV: Emulsion. Method V: Alkaline de-rusting (for ferrous surfaces only). Method VI: Phosphoric acid. Type I: Zinc phosphate. Class 1 - spray application (150mg/sq. ft. min.; 500 mg/sq. ft. max.) Class 2A - Immersion or Dip application (300mg/sq. ft. max.); Class 2B - Immersion or Dip application (600mg/sq. ft. min. to 1000mg/sq. ft. max.) Type II: Aqueous Iron Phosphate (35mg/sq. ft. min.) Type III: (.0003"- .0005") Organic pretreatment coating (unless otherwise specified, MIL-C-8514 or DOD-P-15328). Type IV: Non-aqueous iron phosphate (35mg/sq. ft. min.) Type V: Zinc phosphate (500mg/sq. ft. min.; 1000mg/sq. ft. max.) |
|